Datenblatt für 9272 Series (in) ~ von Belden Inc.

gum-n...“-
For more Information
please call
1-800-Belden1
Description:
20 AWG stranded (7x28) .038" tinned copper conductors, polyethylene insulation, tinned copper braid
shield (93% Coverage), PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material Dia. (in.)
120 7x28 TC - Tinned Copper .038
Insulation
Insulation Material:
Insulation Material
PE - Polyethylene
Outer Shield
Outer Shield Material:
Type Outer Shield Material Coverage (%)
Braid TC - Tinned Copper 93
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride
Overall Cable
Overall Nominal Diameter: 0.244 in.
Pair
Pair Color Code Chart:
Number Color
1Clear & Blue
Pair Lay Length & Direction:
Lay Length (in.) Lay Length Twists/ft. (twist/ft)
4.1
Mechanical Characteristics (Overall)
Operating Temperature Range: -20°C To +60°C
UL Temperature Rating: 60°C (UL AWM Style 2092)
Bulk Cable Weight: 39 lbs/1000 ft.
Max. Recommended Pulling Tension: 68 lbs.
Min. Bend Radius (Install)/Minor Axis: 2.500 in.
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CM
CEC/C(UL) Specification: CM
Page 1 of 3 02-24-2012
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
9272 Twinax - Twinaxial Cable
mun-mm :3: E
AWM Specification: UL Style 2092 (300 V 60°C)
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Flame Test
UL Flame Test: UL1685 UL Loading
Plenum/Non-Plenum
Plenum (Y/N): No
Plenum Number: 89272
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm)
78
Nom. Inductance:
Inductance (µH/ft)
.020
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/ft)
19.7
Nominal Velocity of Propagation:
VP (%)
66
Nominal Delay:
Delay (ns/ft)
1.54
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
9.5
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft)
3.4
Nom. Attenuation:
Freq. (MHz) Attenuation (dB/100 ft.)
10.6
10 2.1
50 5.0
100 7.5
200 11.0
400 16.0
Max. Operating Voltage - UL:
Voltage
300 V RMS (UL AWM Style 2092)
Related Documents:
No related documents are available for this product
Page 2 of 3 02-24-2012
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
9272 Twinax - Twinaxial Cable
mun-mm No related documents are avallahle fonms product
No related documents are available for this product
Put Ups and Colors:
Item # Putup Ship Weight Color Notes Item Desc
9272 006U1000 1,000 FT 39.000 LB BLUE, LIGHT 78 OHM TWINAX
9272 006U500 500 FT 20.000 LB BLUE, LIGHT 78 OHM TWINAX
9272 006100 100 FT 4.500 LB BLUE, LIGHT 78 OHM TWINAX
9272 0061000 1,000 FT 41.000 LB BLUE, LIGHT C 78 OHM TWINAX
9272 006500 500 FT 18.500 LB BLUE, LIGHT C 78 OHM TWINAX
Notes:
C = CRATE REEL PUT-UP.
Revision Number: 2 Revision Date: 04-17-2008
© 2012 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3 02-24-2012
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
9272 Twinax - Twinaxial Cable